Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer
Voltage: Low and Medium Voltage Cable
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
ISO50001
GJB-9001C certification
Product after-sales service evaluation system certification
Quality Assurance
The supplier provides quality assurance
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (32)
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
  • Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
Find Similar Products
  • Overview
  • Range of Business
Overview

Basic Info.

Model NO.
BV
Current
DC & AC
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
BV
Brand
Dongfeng
Flame Retardant
Za Zb Zc
Waterproof
Yes
Export Countries
Uganda Tanzania Ethiopia Russia Kazakhstan Kyrgyzs
Customized
Yes
Transport Package
Roll
Specification
10-800
Trademark
YUNFENG
Origin
China
HS Code
7413000000
Production Capacity
500000m/Week

Packaging & Delivery

Package Size
50.00cm * 30.00cm * 50.00cm
Package Gross Weight
20.000kg

Product Description

Our Product


H07V-U

Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
 
Code : BV, H07V-U, NYA
Standards : 227IEC01, BS 6004, VDE0281-3
Construction :  1- Solid Copper Conductor
    2- PVC insulation
Application :          Preferably for installation indoors, in cable ducts and in industrial plants or switching stations,
       under ground installation.
Technical Data : Max. operating temperature 70  ºC
    Short circuit temperature 160  ºC

Nominal Cross
Section
Wire
Diameter
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at 20ºC
Approx.
Total Weight
Max. Current
Carrying
Capacity at 30ºC
mm2 No. ×mm mm min max Ù/km kg/km Pip A Air A
1.5 1.35 0.7 2.6 3.2 12.1 19 16 24
2.5 1.73 0.8 3.2 3.9 7.41 29 20 32
4 2.19 0.8 3.6 4.4 4.61 42 26 42
6 2.68 0.8 4.1 5.0 3.08 62 35 55
10 3.50 1.0 5.3 6.4 1.83 110 46 75



H07V-R

Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

   450/750V

 
Code   : H07V-R, NYA
Standard   : IEC 227, BS 6004,VDE 0281
Construction   :   1- Stranded Copper Conductor
    2- PVC Insulation
Application :     Preferably for installation indoors. in cable ducts and in industrial plants or
     switching stations. under ground installation.
Technical Data : Max. operating temperature 70ºC
       Short circuit temperature 160ºC

Nominal
Cross
Section
Number of
wires and
Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
mm2 No.  ×mm mm min max Ù/km Kg/km Pip A Air A
1.5 7×0.51 0.7 2.7 3.3 12.1 22.0 16 25
2.5 7×0.66 0.8 3.3 4.0 7.41 36.0 20 34
4 7×0.83 0.8 3.8 4.6 4.61 52.0 26 45
6 7×1.02 0.8 4.3 5.2 3.08 74.0 35 57
10 7×1.32 1.0 5.6 6.7 1.83 110 46 75
16 7×1.68 1.0 6.4 7.8 1.15 170 62 100
25 7×2.20 1.2 8.1 9.7 0.727 265 82 130
35 7×2.55 1.2 9.0 10.9 0.524 360 100 160
50 7×3.00 1.4 10.6 12.8 0.387 501 120 200



  
    H07V-K
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable


     450/750V

 
Code    : RV,H07V-K, NYAF
Standard  :     IEC 227, VDE 0281, BS 6004
Construction : 1- Flexible Copper Conductor
    2- PVC Insulation
Application  :     For protected installation in equipment and lighting fitting.
    Also for in conduit, on and under plaster
Technical Data : Max. operating temperature 70ºC
    Short circuit temperature 160ºC

 
Nominal
Cross
Section
Number of
wires and
Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity at 30ºC
mm2 No.  ×mm mm min max Ù/km Kg/km Pip A  Air A
1.5 27×0.25 0.7 2.8 3.4 13.3 21.0 15 24
2.5 45×0.25 0.8 3.4 4.1 7.98 32.0 20 32
4 50×0.30 0.8 3.9 4.8 4.95 48.0 25 42
6 75×0.30 0.8 4.4 5.3 3.30 68.0 33 54
10 73×0.40 1.0 5.7 6.8 1.91 113 45 73
16 119×0.40 1.0 6.7 8.1 1.21 174 61 98
25 182×0.40 1.2 8.4 10.2 0.780 282 83 129
35 252×0.40 1.2 9.7 11.7 0.554 378 103 158
50 364×0.40 1.4 11.5 13.9 0.386 543 120 198


 

 H05VV-F
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

 300/500V

 
Code : H05VV-F, RVV
Standard :     IEC 227, VDE 0281, BS 6500
Construction   : 1- Flexible Copper Conductor
    2- PVC insulation.              3- PVC Filling.              4- PVC Outer Sheath
Application :     For household appliances under medium mechanical stress-also in damp and wet areas
Technical Data   : Max. operating temperature 70ºC
    Short circuit temperature 160ºC
 
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Thickness
of Sheath
Mean overall diameter Conductor DC
resistance at
20ºC
Approx.
Total Weight
Max. Current
Carrying
Capacity at 30ºC
No No. ×mm mm Mm min max Ù/km Kg/km Air A
2×0.75 22×0.20 0.6 0.8 5.7 7.2 26.0 57.1 8
2×1 30×0.20 0.6 0.8 5.9 7.5 19.5 64.0 12
2×1.5 27×0.25 0.7 0.8 6.8 8.6 13.3 91.0 18
2×2.5 45×0.25 0.8 1.0 8.4 10.6 7.98 135 26
2×4 50×0.30 0.8 1.1 9.7 12.1 4.95 189 32
2×6 75×0.30 0.8 1.1 11.8 13.1 3.30 274 42
2×10 73×0.40 0.9 1.2 14.6 15.8 1.91 422 70
3×0.75 22×0.20 0.6 0.8 6.0 7.6 26.0 68.1 8
3×1 30×0.20 0.6 0.8 6.3 8.0 19.5 77.1 12
3×1.5 27×0.25 0.7 0.9 7.4 9.4 13.3 109 18
3×2.5 45×0.25 0.8 1.0 9.2 11.4 7.98 169 26
3×4 50×0.30 0.8 1.1 10.5 13.1 4.95 238 32
3×6 75×0.30 0.8 1.1 12.5 14.2 3.30 343 42
3×10 73×0.40 0.9 1.2 15.8 17.2 1.91 538 70
4×0.75 22×0.20 0.6 0.8 6.6 8.3 26.0 85.2 8
4×1 30×0.20 0.6 0.8 7.1 9.0 19.5 98.0 12
4×1.5 27×0.25 0.7 0.8 8.4 10.5 13.3 145 18
4×2.5 45×0.25 0.8 1.1 11.0 12.5 7.98 213 26
4×4 50×0.30 0.8 1.2 11.5 14.3 4.95 306 32
4×6 75×0.30 0.8 1.3 13.6 15.2 3.30 427 42
4×10 73×0.40 0.9 1.4 17.2 18.3 1.91 674 70
4×16 119×0.40 0.9 1.5 19.4 20.8 1.21 972 80
5×0.75 22×0.20 0.6 0.8 7.4 9.3 26.0 101 8
5×1 30×0.20 0.6 0.9 7.8 9.8 19.5 125 12
5×1.5 27×0.25 0.7 1.1 9.3 11.6 13.3 176 18
5×2.5 45×0.25 0.8 1.2 11.2 13.9 7.98 261 26
5×4 50×0.30 0.8 1.3 13.0 16.1 4.95 375 32
5×6 75×0.30 0.8 1.4 15.6 16.8 3.30 524 42
5×10 73×0.40 0.9 1.5 18.2 20.3 1.91 831 70
5×16 119×0.40 0.9 1.6 22.3 23.2 1.21 1170 80
 

H05VVH2-F

Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

300/500V

 
Code : H05VVH2-F
Standard :     TS 9760, IEC 227, VDE 0281,BS 6500
Construction : 1- Flexible Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application : In dry. damp and wet locations as flexible connecting cables for light mechanical stresses.
    It is used for hand tools and house hold appliances with flat shape.
Technical Data :   Max. operating temperature 70ºC
    Short circuit temperature 160ºC

Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Approx.
OD
Conductor
DC resistance
at 20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity at 30ºC
No×mm2 No. ×mm min max max.mm Ù/km Kg/km Pip A Air A
2 × 0.75 22 × 0.20 0.6 0.8 4.00 × 6.40 26.0 37.0 - 13
2 × 1 30 × 0.20 0.6 0.8 4.10 × 6.60 19.5 61.1 12 16
2 × 1.5 27 × 0.25 0.7 0.8 4.60 × 7.60 13.3 85.0 16 20
2 × 2.5 45 × 0.25 0.8 1.0 5.70 × 9.40 7.98 128 21 27
2 × 4 50 × 0.30 0.8 1.1 6.40 × 10.6 4.95 185 27 36
3 × 0.75 22 × 0.20 0.6 0.8 4.00 × 8.80 26.0 65.0 - 13
3 × 1 30 × 0.20 0.6 0.8 4.10 × 9.10 19.5 77.0 12 16
3 × 1.5 27 × 0.25 0.7 0.9 4.70 × 10.50 13.3 104 16 20
3 × 2.5 45 × 0.25 0.8 1.1 5.90 × 13.30 7.98 159 21 27
3 × 4 50 × 0.30 0.8 1.2 6.60 × 15.60 4.95 228 27 36

 
  H05V2-K

Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
   300/500V

 
Code : H05V2-K
Standard  :     TS 9758, IEC 227, VDE 0281, BS 6004
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
Application :     For protected installation in equipment and lighting fitting.
    Also for in conduit. on and under plaster.
Technical Data :   Max. operating temperature 90  ºC
    Short circuit temperature 160  ºC
 
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Mean
overall
diameter
Conductor DC
resistance at
20ºC
Approx. Total
Weight
Max. Current Carrying
Capacity at 30ºC
mm2 No. ×mm mm min max Ù/km Kg/km Pip A Air A
0.5 15 × 0.20 0.6 2.1 2.5 39.0 10.0 - -
0.75 22 × 0.20 0.6 2.2 2.7 26.0 12.0 - 16
1 30 × 0.20 0.6 2.4 2.8 19.5 15.0 12 20

 

H07V2-K
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
450/750V
 

 
Code : H07V2-K
Standard   :     TS 9758, IEC 227, VDE 0281, BS 6004
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
Application :    For protected installation in equipment and lighting fitting.
    Also for in conduit. on and under plaster.
Technical Data   :   Max. operating temperature 90  ºC
    Short circuit temperature 160  ºC

 
Nominal
Cross
Section
Number
and Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity
at 30ºC
mm2 No. ×mm mm min max Ù/km Kg/km Pip A Air A
1.5 27 × 0.25 0.7 2.8 3.4 13.3 21.0 15 24
2.5 45 × 0.25 0.8 3.4 4.1 7.98 32.0 20 32
4 50 × 0.30 0.8 3.9 4.8 4.95 48.0 25 42
6 75 × 0.30 0.8 4.4 5.3 3.30 68.0 33 54
10 73 × 0.40 1.0 5.7 6.8 1.91 113 45 73
16 119 × 0.40 1.0 6.7 8.1 1.21 174 61 98
25 182 × 0.40 1.2 8.4 10.2 0.780 282 83 129
35 252 × 0.40 1.2 9.7 11.7 0.554 378 103 158
50 364 × 0.40 1.4 11.5 13.9 0.386 543 132 198

 
 
H05V2V2-F
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

300/500V

 
Code : H05V2V2-F
Standard  :     TS 9760, IEC 227, VDE 0281, BS 6500
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application :     In dry. damp and wet locations as flexible connecting cables for light mechanical
    stresses. It is used for hand tools. heat tools and house hold appliances with flat shape.
Technical Data :   Max. operating temperature 90ºC
    Short circuit temperature 160  ºC
 
Num. of Cores and
Nominal Cross
Section
Number
and Dia.
Thickness of
insulation
Thickness
of Sheath
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity
at 30ºC
No ×mm2 mm mm   min max Ù/km Kg/km Air A
2 × 0.75 22 × 0.20 0.6 0.8 5.7 7.2 26.0 57.0 8
2 × 1 30 × 0.20 0.6 0.8 5.9 7.5 19.5 64.1 12
2 × 1.5 27 × 0.25 0.7 0.8 6.8 8.6 13.3 91.0 18
2 × 2.5 45 × 0.25 0.8 1.0 8.4 10.6 7.98 135 26
2 × 4 50 × 0.30 0.8 1.1 9.7 12.1 4.95 189 32
2 × 6 75 × 0.30 0.8 1.1 11.8 13.1 3.30 274 42
2 × 10 73 × 0.40 0.9 1.2 14.6 15.8 1.91 422 70
3 × 0.75 22 × 0.20 0.6 0.8 6.0 7.6 26.0 68.1 8
3 × 1 30 × 0.20 0.6 0.8 6.3 8.0 19.5 77.0 12
3 × 1.5 27 × 0.25 0.7 0.9 7.4 9.4 13.3 109 18
3 × 2.5 45 × 0.25 0.8 1.1 9.2 11.4 7.98 169 26
3 × 4 50 × 0.30 0.8 1.2 10.5 13.1 4.95 238 32
3 × 6 75 × 0.30 0.8 1.1 12.5 14.2 3.30 343 42
3 × 10 73 × 0.40 0.9 1.2 15.8 17.2 1.91 538 70
4 × 0.75 22 × 0.20 0.6 0.8 6.6 8.3 26.0 85.0 8
4 × 1 30 × 0.20 0.6 0.8 7.1 9.0 19.5 98.0 12
4 × 1.5 27 × 0.25 0.7 0.8 8.4 10.5 13.3 145 18
4 × 2.5 45 × 0.25 0.8 1.1 11 12.5 7.98 213 26
4 × 4 50 × 0.30 0.8 1.2 11.5 14.3 4.95 306 32
4 × 6 75 × 0.30 0.8 1.3 13.6 15.2 3.30 427 42
4 × 10 73 × 0.40 0.9 1.4 17.2 18.3 1.91 674 70
4 × 16 119 × 0.40 0.9 1.5 19.4 20.8 1.21 972 80
5 × 0.75 22 × 0.20 0.6 0.8 7.4 9.3 26.0 101 8
5 × 1 30 × 0.20 0.6 0.9 7.8 9.8 19.5 125 12
5 × 1.5 27 × 0.25 0.7 1.0 9.3 11.6 13.3 176 18
5 × 2.5 45 × 0.25 0.8 1.1 11.2 13.9 7.98 261 26
5 × 4 50 × 0.30 0.8 1.3 13.0 16.1 4.95 375 32
5 × 6 75 × 0.30 0.8 1.4 15.6 16.8 3.30 524 42
5 × 10 73 × 0.40 0.9 1.5 18.2 20.3 1.91 831 70
 

NVV
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

300/500V


 
Code : NVV
Standard   :     TS 9759 HD 21,4 S2, VDE 0250-204, BS 6004
Construction  :     1- Solid or Stranded Copper Conductor
    2- PVC insulation              3- PVC Filling                 4- PVC outer sheath
Application :     Fixed wiring in dry and damp premises, in conduits. on or under plaster and on
    insulators over plaster, switching.
Technical Data : Max. operating temperature 70ºC           Short circuit temperature 160ºC

Num. of
Cores and
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Thickness
of Sheath
Mean overall diameter Conductor
DC
resistance
at 20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No ×mm2 mm mm mm min max Ù/km Kg/km Air A
2 × 1.5 1.35 0.7 1.2 8.4 10.0 12.1 108 22
2 × 2.5 1.73 0.8 1.2 9.6 11.5 7.41 148 30
2 × 4 2.19 0.8 1.2 10.5 12.5 4.61 194 40
2 × 6 2.68 0.8 1.2 11.5 13.5 3.08 250 51
2 × 10 7 × 1.32 1.0 1.4 14.5 16.5 1.83 427 70
2 × 16 7 × 1.66 1.0 1.4 16.5 20.0 1.15 604 94
3 × 1.5 1.35 0.7 1.2 8.8 10.5 12.1 128 22
3 × 2.5 1.73 0.8 1.2 10.0 12.0 7.41 179 30
3 × 4 2.19 0.8 1.2 11.0 13.0 4.61 239 40
3 × 6 2.68 0.8 1.2 12.5 14.5 3.08 319 51
3 × 10 7 × 1.32 1.0 1.4 15.5 17.5 1.83 535 70
3 × 16 7 × 1.66 1.0 1.4 18.0 21.5 1.15 769 94
4 × 1.5 1.35 0.7 1.2 9.6 11.5 12.1 154 18.5
4 × 2.5 1.73 0.8 1.2 11.0 13.0 7.41 219 25
4 × 4 2.19 0.8 1.2 12.0 14.5 4.61 301 34
4 × 6 2.68 0.8 1.2 14.0 16.0 3.08 399 43
4 × 10 7 × 1.32 1.0 1.4 16.5 19.0 1.83 669 60
4 × 16 7 × 1.66 1.0 1.4 20.0 23.5 1.15 970 80
5 × 1.5 1.35 0.7 1.2 10.0 12.0 12.1 181 15.5
5 × 2.5 1.73 0.8 1.2 12.0 14.5 7.41 262 22
5 × 4 2.19 0.8 1.2 13.5 16.0 4.61 364 31
5 × 6 2.68 0.8 1.2 15.0 17.5 3.08 483 40
5 × 10 7 × 1.32 1.0 1.4 18.0 21.0 1.83 828 56.5

 


FLAT CABLES
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
300/500V


 
Code : Flat Cables
Standard :     TS 9760, IEC 227, VDE 0281, BS 6500
Construction : 1- Solid Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching
       stations, under ground installation, with additional protection where mechanical damage
     is unexpected.
Technical Data :   Max. operating temperature 70ºC
    Short circuit temperature 160ºC

 
Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Thickness of
Sheath
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No. ×mm2 No. ×mm mm mm Ù/km Kg/km Pipe A Air A
2 × 1 1.1 0.6 0.8 18.1 50.0 - 19
2 × 1.5 1.35 0.7 0.8 12.1 66.0 32 20
2 × 2.5 1.73 0.8 1.0 7.41 104 42 20
2 × 4 2.19 0.8 1.1 4.61 143 54 20
3 × 1 1.1 0.6 0.8 18.1 73.0 - 20
3 × 1.5 1.35 0.7 0.9 12.1 101 26 20
3 × 2.5 1.73 0.8 1.1 7.41 158 34 20
3 × 4 2.19 0.8 1.2 4.61 216 44 20

 

FLAT TWIN&THREE CORE
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
300/500V
 
Code :     FLAT TWIN& THREE CORE CABLES
Standard : BS6004
Construction : 1- Stranded Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application :     These Cables are used in dry or damp locations for fixed installation.
    Suitable for installation in walls or embedded in plaster.
Technical Data :   Max. operating temperature 70ºC


 
Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Thickness of
Sheath
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No ×mm2 No. ×mm mm mm Ù/km Kg/km Pipe A Air A
2 × 1.5 7 × 0.51 0.7 0.9 12.1 76..0 32 20
2 × 2.5 7 × 0.66 0.8 1.0 7.41 110 42 27
2 × 4 7 × 0.83 0.8 1.0 4.61 148 54 37
3 × 1.5 7 × 0.51 0.7 0.9 12.1 102 26 18
3 × 2.5 7 × 0.66 0.8 1.0 7.41 152 34 25
3 × 4 7 × 0.83 0.8 1.1 4.61 224 44 34



 

Our workshop
Chinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire Cable

Our Lab 
Chinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire Cable

Our certificate 
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
Our Packing
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable
Our performance 
Chinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire CableChinese Manufacturer Copper Conductor PVC Insulated Wire Cable
Our partner 
Chinese Manufacturer Copper Conductor PVC Insulated Wire Cable

FAQ 
Q1: How can l get the price?
We usually quote within 24 hours after we get your inquiry (except weekend and holidays). lf you are urgent to get the price,please email us or contact us in other ways so that we can offer you a quote
Q2: Can l get samples?
We are honored to provide you with samples, samples are provided free of charge, but need to pay for express shipping. lf you have a courier account, you can send a courier to collect samples
Q3: If we place an order, when will it be delivered?
It depends on the order quantity. Under normal circumstances, we can ship small orders within 3-5 working days, if the quantity is large, we will confirm again when you officially place the order.
Q4: How do you make our business long-term and good relationship?
We keep good quality and competitive price to ensure our customers benefit. Furthermore, we respect every customer as ourfriend and we sincerely do business and make friends with them, no matter where they come from.
Q5: Do you accept OEM/ODM?
We support OEM/ODM service. please don't hesitate to tell us your thoughts.
Please feel free to leave your request, we will reply you within 24 hours.



 
Range of Business

Cables:

Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires

Cable Accessories:
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f.   Branch Joint
g. Dry and Y shape Branch Joint


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier