Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 100/Meter
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
308000000 RMB
Plant Area
>2000 square meters
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
  • 10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
Find Similar Products

Basic Info.

Model NO.
YJV
Current
DC & AC
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Copper
Certification
ISO, CCC, CE, RoHS, VDE
Model
YJV
Brand
Yunfeng
Transport Package
Drum
Specification
3x300
Trademark
YUNFENG
Origin
China
HS Code
8544601200
Production Capacity
2 Million Km/Year

Product Description

Specification
1. Scope
The cables are manufactured and tested in accordance with IEC60502 Power Cables with Extruded Insulation and their accessories for rated voltages from 1kV(Um1.2 kV) up to 30kV(Um 36kV). Whereas, Dongfeng Cable can supply XLPE insulation cables according to other recognized national and international standards or customized specification.
2. Construction and Material
1) Conductor
Conductors are normally class 2 of compacted cicular or circular standard conductors of copper or aluminium. 
2) Conductor Screen
All cable of rated voltage above 1.8/3kV are supplied with conductor screening which is non-mentallic and consists of either semi-conducting tape or a layer of extruded semi-conducting compound,or a combination of the two.
3) Insulation
Insulation is a layer of extruded cross-linked polyethylene(XLPE).
4) Insulation Screen
For cable at rated voltage above 1.8/3kV ,insulation screening consists of a non-metallic semi-conducting part in combination with a metallic layer and consists of either semi-conducting tape or a layer of extruded semi-conducting compound.. The extruded insulation screen is normally free strippable(easy removable) type but can be provided with bonded one upon request.  
The metallic part is normally applied on the individual cores for rated voltage above 1.8/3kV and on the core assembly for rated voltage 1.8/3kV and consists of plain annealed copper tape. or copper tape screen a layer of copper wire,a lead alloy or corrugated aluminum sheath can be provided upon request.  

5) Inner Covering or Separation Sheath
(for armored cables)
A layer of PVC inner coveing is applied under the armor ,if there is no screen.
When the metallic screening and the armor are of different metals, an extruded separation sheath of PVC is provided in order to separate the different metals.

6) Metallic Armor
The armor, if required, consists of single layer of round wires or double tapes of galvanized steel or aluminum or other non-magnetic metals. Single core cables are normally armored with aluminum(other non-magnetic metals),  because non-magnetic armor is essential for single core cable for use on A.C circuit .

7) Outer Sheath
All cable are normally provided with an extruded PVC out sheath, black colored(class ST2). Other materials can be available upon request,as PE , polyethylene,high flame or fire retardant PVC and etc.

8) Core Identification
 The multiple conductors are identified as according IEC60502 .
 
Cable Marking(Customized)
 The following information are indicated on the surface of the outer sheath. However, the marking can also be customized.
----voltage rating, area for cable
----manufacturer's name
----year of manufacturer
----lengther for cable
----etc
 
 
 Application:
 It is used to transmit and distribute power in power transmission and distribution systems of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

Standard: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semiconducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622

Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armoring: 

Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black

2. Using features :Medium Voltage Power Cable Underground 11kv 15kv 33kv XLPE Power Cable

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single-core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for a conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise, it should be preheated.
6. The cable is laid without a horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius: Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.


3.Typical Drawing
10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable


4. Tests
The finished cables meet all the appropriate test requirments specified in IEC60502.

10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
5.Packing
10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power CableOur workshop

10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable
10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable10kv Mv Underground Three Core Copper Conductor XLPE Insulated and PVC Sheathed Power Cable



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier