Our product
Self-supporting LV-ABC Lines
Code: ABC 0.6/1kV, NFA2X, AsXS (n), 1-AES
Standards: HD 626 S1: 1996 Part 4-Section F,
PL WT92/K396, CSN 34761-4F
Construction: Phase Conductors: Aluminum conductors with XLPE insulation.
Neutral Messenger: Aluminum conductors with XLPE insulation.
Application: Aerial Bundled Conductors are used
for tributary networks of power buildings
and their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross section |
Conductor diameter |
Thickness of insulation |
Core diameter |
Current carrying capacity |
Breaking load |
(mm²) |
min. |
max. |
nom. |
min. |
min. |
(A*) |
(kN) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
16 |
4,6 |
5,1 |
1,2 |
1,00 |
7,8 |
- |
2,60 |
25 |
5,6 |
6,5 |
1,3 |
1,07 |
10,1 |
107 |
4,17 |
35 |
6,6 |
7,5 |
1,3 |
1,07 |
11,0 |
132 |
5,78 |
50 |
7,7 |
8,6 |
1,5 |
1,25 |
12,5 |
165 |
8,45 |
70 |
9,3 |
10,2 |
1,5 |
1,25 |
14,0 |
205 |
11,32 |
95 |
11,0 |
12,0 |
1,7 |
1,50 |
16,1 |
- |
15,30 |
120 |
12,5 |
13,5 |
1,8 |
1,60 |
17,6 |
- |
20,00 |
150 |
13,9 |
15,0 |
1,8 |
1,60 |
18,8 |
- |
25,00 |
* defined for ambient temperature of 35°C and max. conductor temperature of 80°C
Dimensions of neutral messenger conductors
Number of phase cores x cross section |
Bundle diameter |
+ public lighting conductors |
approx. |
+ neutral cross section |
|
(mm²) |
(mm) |
2 x 16 |
15 |
2 x 25 |
18 |
2 x 35 |
20 |
4 x 16 |
18 |
4 x 25 |
22 |
4 x 35 |
25 |
4 x 50 |
28 |
4 x 70 |
32 |
4 x 70 + 1 x 35 |
36 |
4 x 70 + 2 x 35 |
40 |
4 x 95 |
37 |
4 x 120 |
40 |
4 x 120 + 2 x 35 |
43 |
4 x 150 |
44 |
LV-ABC Lines with Bare Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 5-Section D,
AMKA (SFS 2200)
Construction: Phase Conductors: Aluminum conductors with XLPE insulation.
Neutral Messenger: Aluminum conductors
Application: Aerial Bundled Conductors are used for
tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross section |
Conductor diameter |
Thickness of insulation |
Core diameter |
Current carrying capacity |
Breaking load |
(mm²) |
min. |
tolerance |
nom. |
min. |
min. |
max. |
(A*) |
(kN) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
|
16 |
4,4 |
±0,05 |
1,4 |
- |
7,1 |
7,3 |
70 |
- |
25 |
5,9 |
±0,02 |
1,4 |
- |
8,3 |
9,1 |
95 |
- |
35 |
6,9 |
±0,02 |
1,6 |
- |
9,7 |
10,5 |
115 |
- |
50 |
8,1 |
±0,25 |
1,6 |
- |
10,8 |
11,8 |
140 |
- |
70 |
9,7 |
±0,25 |
1,8 |
- |
12,8 |
13,8 |
180 |
- |
120 |
12,8 |
±0,30 |
2,0 |
- |
16,2 |
17,4 |
250 |
- |
* defined for ambient temperature of 25°C and max. conductor temperature of 70°C
Dimensions of neutral messenger conductors
Cross section |
Conductor diameter |
Thickness of insulation |
Core diameter |
Current carrying capacity |
Breaking load |
(mm²) |
min. |
max. |
nom. |
min. |
min. |
max. |
(A*) |
(kN) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
25 |
5,9 |
±0,02 |
- |
- |
5,5 |
6,3 |
- |
7,4 |
35 |
6,9 |
±0,02 |
- |
- |
6,5 |
7,3 |
- |
10,3 |
50 |
8,1 |
±0,25 |
- |
- |
7,6 |
8,6 |
- |
14,2 |
70 |
9,7 |
±0,25 |
- |
- |
9,2 |
10,2 |
- |
20,6 |
95 |
11,4 |
±0,30 |
- |
- |
10,8 |
12,0 |
- |
27,9 |
Dimensions of Cable Bundle
Number of phase cores x cross section |
Bundle diameter |
+ neutral cross section |
approx. |
(mm²) |
(mm) |
1 x 16 + 25 |
15 |
3 x 16 + 25 |
22 |
4 x 16 + 25 |
22 |
3 x 25 + 35 |
26 |
4 x 25 + 35 |
26 |
3 x 35 + 50 |
30 |
3 x 50 + 70 |
35 |
3 x 70 + 95 |
41 |
3 x 120 + 95 |
47 |
LV-ABC Lines with Insulated Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 6-Section E,
AMKA (SFS 2200)
Construction: Aluminum conductors with XLPE insulation.
Application: Aerial Bundled Conductors are used for
tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross section |
Conductor diameter |
Thickness of insulation |
Core diameter |
Current carrying capacity |
Breaking load |
(mm²) |
min. |
max. |
nom. |
min. |
min. |
max |
(A*) |
(kN) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
|
16 |
4,6 |
5,1 |
1,2 |
- |
7,0 |
7,8 |
- |
- |
25 |
5,8 |
6,3 |
1,4 |
- |
8,6 |
9,4 |
112 |
- |
35 |
6,8 |
7,3 |
1,6 |
- |
10,0 |
10,9 |
138 |
- |
50 |
7,9 |
8,4 |
1,6 |
- |
11,1 |
12,0 |
168 |
- |
70 |
9,7 |
10,2 |
1,8 |
- |
13,3 |
14,2 |
213 |
- |
95 |
11,0 |
12,0 |
1,8 |
- |
14,6 |
15,7 |
258 |
- |
120 |
12,0 |
13,1 |
1,8 |
- |
15,6 |
16,7 |
306 |
- |
150 |
13,9 |
15,0 |
1,7 |
- |
17,3 |
18,6 |
344 |
- |
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of neutral messenger conductors
Cross section |
Conductor diameter |
Thickness of insulation |
Core diameter |
Current carrying capacity |
Breaking load |
(mm²) |
min. |
max. |
nom. |
min. |
min. |
max |
(A*) |
(kN) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
|
54,6 |
9,2 |
9,6 |
1,6 |
- |
12,3 |
13,0 |
- |
16,6 |
70 |
10,0 |
10,2 |
1,5 |
- |
12,9 |
13,6 |
- |
20,5 |
95 |
12,2 |
12,9 |
1,6 |
- |
15,3 |
16,3 |
- |
27,5 |
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of Cable Bundle
Number of phase cores x cross section |
Bundle diameter |
+ public lighting conductors |
approx. |
+ neutral cross section |
|
(mm²) |
(mm) |
3 x 25 + 54,6 |
30,0 |
3 x 35 + K x 16 + 54,6 |
33,0 |
3 x 50 + K x 16 + 54,6 |
36,0 |
3 x 70 + K x 16 + 54,6 |
37,5 |
3 x 70 + K x 25 + 54,6 |
40,0 |
3 x 70 + K x 16 + 70 |
41,0 |
3 x 95 + K x 16 + 70 |
44,0 |
3 x 120 + K x 16 + 70 |
46,0 |
3 x 120 + K x 16 + 95 |
47,0 |
3 x 150 + K x 16 + 70 |
48,0 |
3 x 150 + K x 16 + 95 |
49,0 |
Note: K number of public lighting conductors (K can be equal to 0, 1, 2, or 3)
HV-ABC Lines with Insulated Neutral Messenger
Code: ABC 11kV
Standards: SANS 1713
Construction: Phase Conductors: Aluminum conductors with XLPE insulation.
Neutral Messenger: A stranded galvanized steel conductor, with XLPE insulation.
Application: The Aerial Bundled Conductors shall suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidity of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC, in direct sunlight, heavy saline conditions along the coast and isokeraunic levels of up to 180 thunderstorm days per year.
Installation: These cables are not allowed to be buried, even in conduits.
Phase Conductor Characteristics
1 |
Conductor size |
mm2 |
70 |
95 |
185 |
2 |
Diameter over conductor, nominal |
mm |
9.3-10.2 |
11.6 |
16.4 |
|
Thickness of dielectric |
|
3.4 |
3.4 |
3.4 |
3 |
Nominal |
mm |
|
Minimum at a point |
mm |
2.96 |
2.96 |
2.96 |
4 |
Diameter over insulation, nominal |
mm |
16.1-17.0 |
21.3 |
25.9 |
5 |
Diameter over semi-conducting |
mm |
18.1-19 |
23.3 |
27.9 |
core screen, nominal |
6 |
Thickness of copper tape nominal |
mm |
0.15 |
1.15 |
2.15 |
|
Thickness of sheath |
|
1.8 |
1.8 |
1.8 |
7 |
Nominal |
mm |
|
Minimum at a point |
mm |
1.43 |
1.43 |
1.51 |
8 |
Catenary size |
mm2 |
50 |
50 |
70 |
9 |
Overall diameter of bundle, nominal |
mm |
55.7 |
67.8 |
79.2 |
10 |
Nominal mass |
kg/m |
2.64 |
3.25 |
4.65 |
Supporting Catenary Characteristics
1 |
Catenary size |
mm2 |
50 |
70 |
2 |
Number of Wires |
|
7 |
7 |
3 |
Wire Size(diameter) |
mm |
3.0 |
3.6 |
4 |
Minimum Tensile Strength of each Wire |
kN |
9.26 |
13.13 |
5 |
Elongation at break, minimum |
% |
3.5 |
4.0 |
6 |
Thickness of protective covering |
|
|
|
Nominal |
mm |
1.2 |
1.2 |
Minimum at a point |
mm |
0.96 |
1.96 |
7 |
Impulse withstand voltage 1.2/50μs |
|
21kv/5min |
21kv/5min |
Our workshop
Our Lab
Our certificate
Our Packing
Our performance
Our partner
FAQ
Q1: How can l get the price?
We usually quote within 24 hours after we get your inquiry (except weekend and holidays). lf you are urgent to get the price,please email us or contact us in other ways so that we can offer you a quote
Q2: Can l get samples?
We are honored to provide you with samples, samples are provided free of charge, but need to pay for express shipping. lf you have a courier account, you can send a courier to collect samples
Q3: If we place an order, when will it be delivered?
It depends on the order quantity. Under normal circumstances, we can ship small orders within 3-5 working days, if the quantity is large, we will confirm again when you officially place the order.
Q4: How do you make our business long-term and good relationship?
We keep good quality and competitive price to ensure our customers benefit. Furthermore, we respect every customer as ourfriend and we sincerely do business and make friends with them, no matter where they come from.
Q5: Do you accept OEM/ODM?
We support OEM/ODM service. please don't hesitate to tell us your thoughts.
Please feel free to leave your request, we will reply you within 24 hours.
Range of Business
Cables:
Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires
Cable Accessories:
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f. Branch Joint
g. Dry and Y shape Branch Joint