0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 10/Meter
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
308000000 RMB
Plant Area
>2000 square meters
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
  • 0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
Find Similar Products

Basic Info.

Model NO.
YJV
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Copper
Certification
ISO, CCC, CE, RoHS, VDE
Model
YJV
Brand
Dongfeng
Transport Package
Drum
Specification
4X150
Trademark
YUNFENG
Origin
China
HS Code
8544492100
Production Capacity
2 Million Km/Year

Product Description

 

Specification
Product Description

Low Voltage Cable

1. Application

The cable is used in electric transmission and distribution system operating at AC rated voltage up to and including 1.8/3 KV

2. Operating Characteristic

1) The rated voltage U0/U of cable is 0.6/1KV.

2) The long time allowable working temperature of conductor is 70 °C FOR cable with PVC insulation, 90 °C for cable with XLPE insulation.

3) The cable laying temperature is not less than 0°C, and the allowable bending radius of a cable is not less 20 times than cable overall diameter for single core unarmored cable, 15 times of that for single core armored, 12 times of that for 3 cores armored cable.


1. Scope
The cables are manufactured and tested in accordance with IEC60502 Power Cables with Extruded Insulation and their accessories for rated voltages from 1kV(Um1.2 kV) up to 30kV(Um 36kV). Whereas, Greatwall Cable can supply XLPE insulation cables according to other recognized national and international standards or customized specification.
2. Construction and Material
1) Conductor
Conductors are normally class 2 of compacted cicular or circular standard conductors of copper or aluminium. 
2) Conductor Screen
All cable of rated voltage above 1.8/3kV are supplied with conductor screening which is non-mentallic and consists of either semi-conducting tape or a layer of extruded semi-conducting compound,or a combination of the two.
3) Insulation
Insulation is a layer of extruded cross-linked polyethylene(XLPE).
4) Insulation Screen
For cable at rated voltage above 1.8/3kV ,insulation screening consists of a non-metallic semi-conducting part in combination with a metallic layer and consists of either semi-conducting tape or a layer of extruded semi-conducting compound.. The extruded insulation screen is normally free strippable(easy removable) type but can be provided with bonded one upon request.  
The metallic part is normally applied on the individual cores for rated voltage above 1.8/3kV and on the core assembly for rated voltage 1.8/3kV and consists of plain annealed copper tape. or copper tape screen a layer of copper wire,a lead alloy or corrugated aluminum sheath can be provided upon request.  

5) Inner Covering or Separation Sheath
(for armored cables)
A layer of PVC inner coveing is applied under the armor ,if there is no screen.
When the metallic screening and the armor are of different metals, an extruded separation sheath of PVC is provided in order to separate the different metals.

6) Metallic Armor
The armor, if required, consists of single layer of round wires or double tapes of galvanized steel or aluminum or other non-magnetic metals. Single core cables are normally armored with aluminum(other non-magnetic metals),  because non-magnetic armor is essential for single core cable for use on A.C circuit .

7) Outer Sheath
All cable are normally provided with an extruded PVC out sheath, black colored(class ST2). Other materials can be available upon request,as PE , polyethylene,high flame or fire retardant PVC and etc.

8) Core Identification
 The multiple conductors are identified as according IEC60502 .
 
Cable Marking(Customized)
 The following information are indicated on the surface of the outer sheath. However, the marking can also be customized.
----voltage rating, area for cable
----manufacturer's name
----year of manufacturer
----lengther for cable
----etc



3.Typical Drawing
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
PARAMETERS
 Cores and Nominal Cross Section Area:
Rated voltage 0.6/1kV  Single core  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC;AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
1.5 0.7 0.7 5.6 45 35            
2.5 0.7 0.7 6 56 41            
4 0.7 0.7 6.5 74 49            
6 0.7 0.7 7 95 59            
10 0.7 0.7 8.2 139 79            
16 0.7 0.7 9.1 197 102            
25 0.9 0.9 10.6 293 143 0.9 0.2 1.8 14 451 301
35 0.9 0.9 11.6 386 178 0.9 0.2 1.8 15 558 349
50 1 1 13 507 225 0.9 0.2 1.8 16.4 698 416
70 1.1 1.1 14.9 708 300 0.9 0.2 1.8 18.3 926 519
95 1.1 1.1 16.8 959 394 0.9 0.2 1.8 20 1194 628
120 1.2 1.2 18.5 1193 479 0.9 0.2 1.8 21.7 1450 737
150 1.4 1.4 20.6 1470 590 0.9 0.2 1.8 23.6 1745 865
185 1.6 1.6 22.8 1831 730 0.9 0.2 1.8 25.6 2122 1021
240 1.7 1.7 25.7 2380 933 0.9 0.2 1.9 28.5 2706 1259
300 1.8 1.8 28.3 2960 1144 0.9 0.2 1.9 30.9 3304 1488
400 2 2 31.3 3755 1433 1.2 0.5 2.1 35.9 4494 2173
Rated voltage 0.6/1kV  Two cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
1.5 0.7 1.8 10.2 114 96 0.9 0.2 1.8 12.8 232 214
2.5 0.7 1.8 11 141 111 0.9 0.2 1.8 13.6 269 238
4 0.7 1.8 12 181 132 0.9 0.2 1.8 14.6 320 271
6 0.7 1.8 13 228 156 0.9 0.2 1.8 15.6 379 306
10 0.7 1.8 15.4 331 211 0.9 0.2 1.8 18 509 389
16 0.7 1.8 17.2 458 268 0.9 0.2 1.8 19.8 657 467
25 0.9 1.8 20.2 672 371 0.9 0.2 1.8 22.8 905 604
35 0.9 1.8 22.2 873 455 0.9 0.2 1.8 24.8 1130 712
50 1 1.8 25 1140 574 0.9 0.2 1.8 27.6 1428 863
70 1.1 1.9 29 1592 775 1.2 0.2 2 33.6 2262 1445
95 1.1 2 32.6 2134 1000 1.2 0.2 2.2 37.4 2899 1765
120 1.2 2.1 36.2 2660 1229 1.2 0.5 2.3 41 3504 2074
150 1.4 2.3 40.4 3287 1522 1.2 0.5 2.4 45 4202 2437
185 1.6 2.4 44.6 4073 1864 1.2 0.5 2.5 49.2 5079 2870
240 1.7 2.6 50.4 5287 2384 1.4 0.5 2.8 55.6 6457 3554
300 1.8 2.8 55.6 6567 2925 1.4 0.5 2.9 60.6 7822 4180
400 2 2.9 61.4 8279 3622 1.4 0.5 3.1 66.6 9692 5034
Rated voltage 0.6/1kV  Three cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
1.5 0.7 1.8 10.7 135 107 0.9 0.2 1.8 13.3 259 231
2.5 0.7 1.8 11.5 171 125 0.9 0.2 1.8 14.1 304 259
4 0.7 1.8 12.6 225 152 0.9 0.2 1.8 15.2 370 297
6 0.7 1.8 13.7 291 182 0.9 0.2 1.8 16.3 449 341
10 0.7 1.8 16.3 429 250 0.9 0.2 1.8 18.9 618 438
16 0.7 1.8 18.2 609 324 0.9 0.2 1.8 20.8 820 534
25 0.9 1.8 21.4 907 455 0.9 0.2 1.8 24 1154 703
35 0.9 1.8 23.6 1194 567 0.9 0.2 1.8 26.2 1466 840
50 1 1.8 26.6 1570 722 0.9 0.2 1.9 29.4 1891 1042
70 1.1 1.9 30.9 2208 983 1.2 0.2 2.1 35.7 2936 1711
95 1.1 2.1 35 2995 1294 1.2 0.5 2.2 39.6 3794 2093
120 1.2 2.2 38.8 3741 1595 1.2 0.5 2.4 43.6 4642 2496
150 1.4 2.3 43.1 4601 1953 1.2 0.5 2.5 47.9 5598 2950
185 1.6 2.5 47.8 5738 2425 1.4 0.5 2.7 53 6851 3538
240 1.7 2.7 54 7462 3107 1.4 0.5 2.9 59.2 8711 4356
300 1.8 2.9 59.6 9283 3820 1.4 0.5 3.1 64.8 10655 5192
400 2 3.1 66 11771 4786 1.4 0.5 3.3 71.2 13284 6299
Rated voltage 0.6/1kV  Four cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
1.5 0.7 1.8 11.4 160 123 0.9 0.2 1.8 14 292 255
2.5 0.7 1.8 12.4 207 147 0.9 0.2 1.8 15 351 290
4 0.7 1.8 13.6 277 179 0.9 0.2 1.8 16.2 434 337
6 0.7 1.8 14.8 362 217 0.9 0.2 1.8 17.4 533 389
10 0.7 1.8 17.7 542 302 0.9 0.2 1.8 20.3 746 507
16 0.7 1.8 19.8 777 396 0.9 0.2 1.8 22.4 1005 625
25 0.9 1.8 23.5 1169 566 0.9 0.2 1.8 26.1 1440 838
35 0.9 1.8 25.9 1546 710 0.9 0.2 1.9 28.7 1858 1022
50 1 1.9 29.5 2054 923 1.2 0.2 2.1 34.3 2751 1620
70 1.1 2.1 34.4 2909 1275 1.2 0.2 2.2 39 3695 2061
95 1.1 2.2 38.8 3930 1661 1.2 0.5 2.4 43.6 4831 2563
120 1.2 2.3 43.1 4913 2051 1.2 0.5 2.5 47.9 5909 3048
150 1.4 2.5 48 6067 2537 1.4 0.5 2.7 53.2 7184 3654
185 1.6 2.7 53.3 7566 3148 1.4 0.5 2.8 58.3 8772 4355
240 1.7 2.9 60.2 9839 4033 1.4 0.5 3.1 65.4 11225 5419
300 1.8 3.1 66.4 12242 4957 1.4 0.5 3.3 71.6 13764 6479
400 2 3.3 73.5 15526 6212 1.4 0.5 3.5 78.7 17205 7891
Rated voltage 0.6/1kV  Five cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
1.5 0.7 1.8 12.2 186 140 0.9 0.2 1.8 14.8 328 281
2.5 0.7 1.8 13.3 244 168 0.9 0.2 1.8 15.9 398 322
4 0.7 1.8 14.6 329 207 0.9 0.2 1.8 17.2 498 376
6 0.7 1.8 16 434 254 0.9 0.2 1.8 18.6 619 439
10 0.7 1.8 19.2 655 356 0.9 0.2 1.8 21.8 877 578
16 0.7 1.8 21.7 948 472 0.9 0.2 1.8 24.3 1199 723
25 0.9 1.8 25.7 1432 679 0.9 0.2 1.9 28.5 1742 989
35 0.9 1.9 28.6 1914 869 0.9 0.2 2 31.4 2257 1213
50 1 2 32.6 2546 1131 1.2 0.2 2.2 37.4 3310 1896
70 1.1 2.2 38.1 3607 1565 1.2 0.5 2.3 42.7 4473 2431
95 1.1 2.3 42.9 4876 2040 1.2 0.5 2.5 47.7 5868 3032
120 1.2 2.5 47.9 6120 2543 1.4 0.5 2.7 53.1 7235 3658
150 1.4 2.7 53.4 7556 3143 1.4 0.5 2.8 58.4 8765 4352
185 1.6 2.9 59.2 9419 3897 1.4 0.5 3 64.2 10752 5230
240 1.7 3.1 66.9 12249 4992 1.4 0.5 3.3 72.1 13783 6525
300 1.8 3.4 74 15273 6168 1.4 0.5 3.5 79 16925 7820
400 2 3.6 82 19369 7726 1.4 0.5 3.8 88.4 22080 10437
Rated voltage 0.6/1kV  3+1 cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
2.5/1.5 0.7/0.7 1.8 12.4 198 143 0.9 0.2 1.8 15 342 287
4/2.5 0.7/0.7 1.8 13.6 262 174 0.9 0.2 1.8 16.2 420 332
64 0.7/0.7 1.8 14.8 343 211 0.9 0.2 1.8 17.4 515 382
106 0.7/0.7 1.8 17.7 506 290 0.9 0.2 1.8 20.3 710 495
1016 0.7/0.7 1.8 19.8 724 378 0.9 0.2 1.8 22.4 953 607
25/16 0.9/0.7 1.8 23.5 1083 536 0.9 0.2 1.8 26.1 1354 807
35/16 0.9/0.7 1.8 25.3 1371 649 0.9 0.2 1.9 28.1 1676 954
50/25 1.0/0.9 1.9 28.8 1852 853 0.9 0.2 2 31.6 2198 1199
70/35 1.1/0.9 2 33.5 2593 1158 1.2 0.2 2.2 38.3 3378 1944
95/50 1.1/1.0 2.2 37.9 3506 1522 1.2 0.5 2.3 42.5 4367 2383
120/70 1.2/1.1 2.3 42.1 4452 1897 1.2 0.5 2.5 46.9 5425 2871
150/70 1.4/1.1 2.5 46.9 5361 2305 1.4 0.5 2.6 51.9 6430 3373
185/95 1.6/1.1 2.6 51.8 6732 2851 1.4 0.5 2.8 57 7933 4053
240/120 1.7/1.2 2.9 58.8 8740 3670 1.4 0.5 3 63.8 10065 4995
300/150 1.8/1.4 3.1 64.8 10850 4504 1.4 0.5 3.2 69.8 12304 5958
400/185 2.0/1.6 3.3 71.8 13718 5628 1.4 0.5 3.5 77 15359 7269
                       
Rated voltage 0.6/1kV  3+2 cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
2.5/1.5 0.7/0.7 1.8 13.3 225 161 0.9 0.2 1.8 15.9 379 315
4/2.5 0.7/0.7 1.8 14.6 300 197 0.9 0.2 1.8 17.2 469 366
64 0.7/0.7 1.8 16 398 241 0.9 0.2 1.8 18.6 583 426
106 0.7/0.7 1.8 19.2 584 332 0.9 0.2 1.8 21.8 806 554
1016 0.7/0.7 1.8 21.8 844 439 0.9 0.2 1.8 24.4 1096 691
25/16 0.9/0.7 1.8 25.7 1262 620 0.9 0.2 1.9 28.5 1572 930
35/16 0.9/0.7 1.8 27.5 1557 740 0.9 0.2 1.9 30.3 1889 1072
50/25 1.0/0.9 2 31.6 2148 998 1.2 0.2 2.1 36.2 2873 1724
70/35 1.1/0.9 2.1 36.7 2993 1350 1.2 0.2 2.3 41.5 3849 2206
95/50 1.1/1.0 2.3 41.5 4037 1770 1.2 0.5 2.4 46.1 4976 2709
120/70 1.2/1.1 2.4 46.1 5186 2223 1.4 0.5 2.6 51.3 6262 3299
150/70 1.4/1.1 2.6 51.5 6133 2669 1.4 0.5 2.8 56.7 7328 3863
185/95 1.6/1.1 2.8 57.1 7789 3341 1.4 0.5 3 62.3 9106 4658
240/120 1.7/1.2 3 64.5 10040 4255 1.4 0.5 3.2 69.7 11521 5736
300/150 1.8/1.4 3.3 71.3 12479 5251 1.4 0.5 3.4 76.3 14074 6845
400/185 2.0/1.6 3.5 79 15742 6547 1.4 0.5 3.7 85.4 18358 9163
                       
Rated voltage 0.6/1kV  4+1 cores  Basic parameter of Power Cable
Nominal cross sectionmm2 Thickness of insulationmm CU/XLPE/PVC,AL/XLPE/PVC Approximate weight of cable kg/km         Approximate weight of cable kg/km
Thickness of sheathmm Approx. overall diameter of cable mm CU/XLPE/PVC AL/XLPE/PVC Inner covering mm Thickness of steel tape mm Thickness of sheath mm Approx. overall diameter of cable mm CU/XLPE/SWA/PVC AL/XLPE/SWA/PVC
2.5/1.5 0.7/0.7 1.8 13.3 235 165 0.9 0.2 1.8 15.9 389 319
4/2.5 0.7/0.7 1.8 14.6 315 202 0.9 0.2 1.8 17.2 483 371
64 0.7/0.7 1.8 16 416 247 0.9 0.2 1.8 18.6 601 432
106 0.7/0.7 1.8 19.2 620 344 0.9 0.2 1.8 21.8 842 566
1016 0.7/0.7 1.8 21.7 896 455 0.9 0.2 1.8 24.3 1146 706
25/16 0.9/0.7 1.8 25.7 1347 650 0.9 0.2 1.9 28.5 1657 960
35/16 0.9/0.7 1.9 28.2 1742 811 0.9 0.2 1.9 30.8 2067 1136
50/25 1.0/0.9 2 32.1 2347 1065 1.2 0.2 2.1 36.7 3083 1802
70/35 1.1/0.9 2.2 37.5 3308 1466 1.2 0.5 2.3 42.1 4161 2318
95/50 1.1/1.0 2.3 42.2 4456 1905 1.2 0.5 2.5 47 5432 2881
120/70 1.2/1.1 2.5 47.1 5663 2394 1.4 0.5 2.6 52.1 6736 3466
150/70 1.4/1.1 2.7 52.6 6857 2918 1.4 0.5 2.8 57.6 8048 4109
185/95 1.6/1.1 2.8 58.1 8591 3606 1.4 0.5 3 63.3 9931 4946
240/120 1.7/1.2 3.1 65.8 11159 4638 1.4 0.5 3.3 71 12668 6146
300/150 1.8/1.4 3.3 72.6 13860 5693 1.4 0.5 3.5 77.8 15518 7351
400/185 2.0/1.6 3.6 80.6 17573 7154 1.4 0.5 3.8 87 20238 9819


4. Tests
The finished cables meet all the appropriate test requirments specified in IEC60502.
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable

1 Information

a, Number of cores:
1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on.

b, Construction:
Conductor: Solid or stranded copper
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Armor: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)

c, Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

d, Features
XLPE insulated power cable does not have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat resistance and environmental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is convenient to use and can be laid with no restriction on different levels.
XLPE insulated steel wire armored power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-aging resisting, environmental stress resisting antichemical corrosion, and it is a simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation cross-linking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen-free, and non-smoke nonhalogenated and three classes of A, B, C.

2 Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.

3 The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

4 Application:
1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is
risk of mechanical damage, armored cables should be used.
2) For laying in the ground along the route with large difference of level able to bear external mechanical forces.


3.Typical Drawing
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
4
. Tests

The finished cables meet all the appropriate test requirments specified in IEC60502.

0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable
5.Packing

0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable



Range of Business:

Cables
Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires

Cable Accessories
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f. Branch Joint
g. Dry and Y shape Branch Joint


Why choose us?
  1. Export to many countries including Iraq, Tanzania and Australia and USA.
  2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices.
  3. Professional overseas team guarantees you best pre-and-after sale services.
  4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
  5. 5S Management to enhance the qualifications of staff and make better service for customers.
  6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.






 Our workshop
0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable0.6/1kv Low Voltage Underground Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Power Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier