• Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
  • Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
  • Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
  • Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
  • Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
  • Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable

Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable

Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: PVC
Sheath Material: PVC
Material Shape: Round Wire
Customization:

Contact Supplier

Ms. Cecilia Zhang
Sales Director
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
RVV
Wire Core Material
Bare Copper Wire
Certification
CCC
Model
H05VV-F
Brand
Yunfeng
Transport Package
Roll
Specification
3x0.75
Trademark
YUNFENG
Origin
China
HS Code
7413000000
Production Capacity
500000m/Week

Product Description

Company Profile
Jiangsu Dongfeng Cable Co.,Ltd(Originally Wuxi Dongfeng Factory )was founded in 1988,which is an high-tech private enterprise with collection of research,development and production of various wires and cables.The registered capital is 308 million RMB,total asset is 1810 million RMB.Factory area covers 160 thousand square meters,of which construction area is 120 thousand square meters.The corporation owns a Technology Center of Jiangsu Province Level.

In recent years,the enterprise was granted by government as High Technology Enterprise,Famous Enterprise of Jiangsu Province,Quality Faithful Enterprise,Advanced Enterprise of Wuxi City,Double Civilization Enterprise,AAA Class Credit Enterprise,Enterprise of Observing Contracts And Keeping Promise. Wires and cables of YUNFENG trademark scored many honors,such as Customer Satisfied Products In China,Famous Brand Products Of Jiangsu Province,Famous Brand Of China.The corporation is praised by customers in quality,service and reputation continually for many years,and it was awarded as Customer Satisfied Enterprise In Service And Integrity by China Consumer Protection Foundation,now it become one of important enterprise in wires and cables industry.

Main products of the corporation are :500Kv extra high voltage cable,220 and 110kV and 60kV high voltage power cable,XLPE insulated power cable for rated voltage from 1kV to 35kV,PVC insulated power cable,aerial insulation cable,aerial insulation cable,cables for electrical equipments ,low-smoke halogen-free flame retardant cable,fire proof cable,fire proof cable,general rubber cable,mineral cable,welding cable,control cable,AAC and ACSR,etc.


The company adhere to scientific and technological progress as the motive,ongoing technical transformation ,it now owns 6 production lines of international advanced level for middle and high and extra high voltage cables,which includes a VCV line for 500kV and below power cables made by TROESTER corporation in Germany,and a CCV line for 220kV and below power cables made by MAILLEFER corporation in Finland,each line is configured with eccentricity measurement on line made by SIKORA corporation in Germany.Test equipments for high voltage and partial discharge is 700kV AC resonant test system made by Phenix corporation in USA,and the corporation has over 300 of other main production machines and over 200 of test equipments ,all are first rate in China or in the world.The production ability is 2 million kilometers a year ,the cables can be produced according to national and international standard,or according to customer's requirements.The enterprise has established more than 150 sales corporation in main cities in China,the products can meet the requirements of sectors in power, communication ,airline,railway,automobile,household electrical appliances,oil.chemistry,mine and metallurgy,almost covers all sectors.In recent years,the cables of the corporation is used in many important projects and gained praises,such as Hada high speed railway,Ninghang high speed railway,number 5 lines of Shenzhen subway,Jinqi high speed railway,Qingdao gulf bridge,Beijing Workers' Gymnasium,National urban and rural power grid renovation.110kV cables was used in grid project of inner Mongolia,Guangxi,Chongqing,Sichuan and big steel corporation,Chemistry corporation.The cables work stably and user's feedback is good.


Quality is life of an enterprise,what we are looking for is not only qualified but also is excellent.Jiangsu Dongfeng Cable has impeccable quality assurance system,established quality assurance institutions of technology center and quality test center.The corporation gained ISO9001 certificate,ISO 14001certificate,GB/T28001 certificate.In the moment of hugely developing electricity in our country,the corporation will use the opportunity and its own advantage to meet the requipment of the market and strive to build innovative companies,it will service for the new and old customers by first rate products.
 

Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable


H07V-U



Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable



 
Code : BV, H07V-U, NYA
Standards : 227IEC01, BS 6004, VDE0281-3
Construction :  1- Solid Copper Conductor
    2- PVC insulation
Application :          Preferably for installation indoors, in cable ducts and in industrial plants or switching stations,
       under ground installation.
Technical Data : Max. operating temperature 70  ºC
    Short circuit temperature 160  ºC




 
Nominal Cross
Section
Wire
Diameter
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at 20ºC
Approx.
Total Weight
Max. Current
Carrying
Capacity at 30ºC
mm2 No. ×mm mm min max Ù/km kg/km Pip A Air A
1.5 1.35 0.7 2.6 3.2 12.1 19 16 24
2.5 1.73 0.8 3.2 3.9 7.41 29 20 32
4 2.19 0.8 3.6 4.4 4.61 42 26 42
6 2.68 0.8 4.1 5.0 3.08 62 35 55
10 3.50 1.0 5.3 6.4 1.83 110 46 75



H07V-R

Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable

   450/750V

 
Code   : H07V-R, NYA
Standard   : IEC 227, BS 6004,VDE 0281
Construction   :   1- Stranded Copper Conductor
    2- PVC Insulation
Application :     Preferably for installation indoors. in cable ducts and in industrial plants or
     switching stations. under ground installation.
Technical Data : Max. operating temperature 70ºC
       Short circuit temperature 160ºC

Nominal
Cross
Section
Number of
wires and
Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
mm2 No.  ×mm mm min max Ù/km Kg/km Pip A Air A
1.5 7×0.51 0.7 2.7 3.3 12.1 22.0 16 25
2.5 7×0.66 0.8 3.3 4.0 7.41 36.0 20 34
4 7×0.83 0.8 3.8 4.6 4.61 52.0 26 45
6 7×1.02 0.8 4.3 5.2 3.08 74.0 35 57
10 7×1.32 1.0 5.6 6.7 1.83 110 46 75
16 7×1.68 1.0 6.4 7.8 1.15 170 62 100
25 7×2.20 1.2 8.1 9.7 0.727 265 82 130
35 7×2.55 1.2 9.0 10.9 0.524 360 100 160
50 7×3.00 1.4 10.6 12.8 0.387 501 120 200



  
    H07V-K



     450/750V


 
Code    : RV,H07V-K, NYAF
Standard  :     IEC 227, VDE 0281, BS 6004
Construction : 1- Flexible Copper Conductor
    2- PVC Insulation
Application  :     For protected installation in equipment and lighting fitting.
    Also for in conduit, on and under plaster
Technical Data : Max. operating temperature 70ºC
    Short circuit temperature 160ºC


 
Nominal
Cross
Section
Number of
wires and
Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity at 30ºC
mm2 No.  ×mm mm min max Ù/km Kg/km Pip A  Air A
1.5 27×0.25 0.7 2.8 3.4 13.3 21.0 15 24
2.5 45×0.25 0.8 3.4 4.1 7.98 32.0 20 32
4 50×0.30 0.8 3.9 4.8 4.95 48.0 25 42
6 75×0.30 0.8 4.4 5.3 3.30 68.0 33 54
10 73×0.40 1.0 5.7 6.8 1.91 113 45 73
16 119×0.40 1.0 6.7 8.1 1.21 174 61 98
25 182×0.40 1.2 8.4 10.2 0.780 282 83 129
35 252×0.40 1.2 9.7 11.7 0.554 378 103 158
50 364×0.40 1.4 11.5 13.9 0.386 543 120 198


 

 H05VV-F

 300/500V


 
Code : H05VV-F, RVV
Standard :     IEC 227, VDE 0281, BS 6500
Construction   : 1- Flexible Copper Conductor
    2- PVC insulation.              3- PVC Filling.              4- PVC Outer Sheath
Application :     For household appliances under medium mechanical stress-also in damp and wet areas
Technical Data   : Max. operating temperature 70ºC
    Short circuit temperature 160ºC
 
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Thickness
of Sheath
Mean overall diameter Conductor DC
resistance at
20ºC
Approx.
Total Weight
Max. Current
Carrying
Capacity at 30ºC
No No. ×mm mm Mm min max Ù/km Kg/km Air A
2×0.75 22×0.20 0.6 0.8 5.7 7.2 26.0 57.1 8
2×1 30×0.20 0.6 0.8 5.9 7.5 19.5 64.0 12
2×1.5 27×0.25 0.7 0.8 6.8 8.6 13.3 91.0 18
2×2.5 45×0.25 0.8 1.0 8.4 10.6 7.98 135 26
2×4 50×0.30 0.8 1.1 9.7 12.1 4.95 189 32
2×6 75×0.30 0.8 1.1 11.8 13.1 3.30 274 42
2×10 73×0.40 0.9 1.2 14.6 15.8 1.91 422 70
3×0.75 22×0.20 0.6 0.8 6.0 7.6 26.0 68.1 8
3×1 30×0.20 0.6 0.8 6.3 8.0 19.5 77.1 12
3×1.5 27×0.25 0.7 0.9 7.4 9.4 13.3 109 18
3×2.5 45×0.25 0.8 1.0 9.2 11.4 7.98 169 26
3×4 50×0.30 0.8 1.1 10.5 13.1 4.95 238 32
3×6 75×0.30 0.8 1.1 12.5 14.2 3.30 343 42
3×10 73×0.40 0.9 1.2 15.8 17.2 1.91 538 70
4×0.75 22×0.20 0.6 0.8 6.6 8.3 26.0 85.2 8
4×1 30×0.20 0.6 0.8 7.1 9.0 19.5 98.0 12
4×1.5 27×0.25 0.7 0.8 8.4 10.5 13.3 145 18
4×2.5 45×0.25 0.8 1.1 11.0 12.5 7.98 213 26
4×4 50×0.30 0.8 1.2 11.5 14.3 4.95 306 32
4×6 75×0.30 0.8 1.3 13.6 15.2 3.30 427 42
4×10 73×0.40 0.9 1.4 17.2 18.3 1.91 674 70
4×16 119×0.40 0.9 1.5 19.4 20.8 1.21 972 80
5×0.75 22×0.20 0.6 0.8 7.4 9.3 26.0 101 8
5×1 30×0.20 0.6 0.9 7.8 9.8 19.5 125 12
5×1.5 27×0.25 0.7 1.1 9.3 11.6 13.3 176 18
5×2.5 45×0.25 0.8 1.2 11.2 13.9 7.98 261 26
5×4 50×0.30 0.8 1.3 13.0 16.1 4.95 375 32
5×6 75×0.30 0.8 1.4 15.6 16.8 3.30 524 42
5×10 73×0.40 0.9 1.5 18.2 20.3 1.91 831 70
5×16 119×0.40 0.9 1.6 22.3 23.2 1.21 1170 80
 

H05VVH2-F

300/500V


 
Code : H05VVH2-F
Standard :     TS 9760, IEC 227, VDE 0281,BS 6500
Construction : 1- Flexible Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application : In dry. damp and wet locations as flexible connecting cables for light mechanical stresses.
    It is used for hand tools and house hold appliances with flat shape.
Technical Data :   Max. operating temperature 70ºC
    Short circuit temperature 160ºC

Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Approx.
OD
Conductor
DC resistance
at 20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity at 30ºC
No×mm2 No. ×mm min max max.mm Ù/km Kg/km Pip A Air A
2 × 0.75 22 × 0.20 0.6 0.8 4.00 × 6.40 26.0 37.0 - 13
2 × 1 30 × 0.20 0.6 0.8 4.10 × 6.60 19.5 61.1 12 16
2 × 1.5 27 × 0.25 0.7 0.8 4.60 × 7.60 13.3 85.0 16 20
2 × 2.5 45 × 0.25 0.8 1.0 5.70 × 9.40 7.98 128 21 27
2 × 4 50 × 0.30 0.8 1.1 6.40 × 10.6 4.95 185 27 36
3 × 0.75 22 × 0.20 0.6 0.8 4.00 × 8.80 26.0 65.0 - 13
3 × 1 30 × 0.20 0.6 0.8 4.10 × 9.10 19.5 77.0 12 16
3 × 1.5 27 × 0.25 0.7 0.9 4.70 × 10.50 13.3 104 16 20
3 × 2.5 45 × 0.25 0.8 1.1 5.90 × 13.30 7.98 159 21 27
3 × 4 50 × 0.30 0.8 1.2 6.60 × 15.60 4.95 228 27 36

 
  H05V2-K

   300/500V



 
Code : H05V2-K
Standard  :     TS 9758, IEC 227, VDE 0281, BS 6004
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
Application :     For protected installation in equipment and lighting fitting.
    Also for in conduit. on and under plaster.
Technical Data :   Max. operating temperature 90  ºC
    Short circuit temperature 160  ºC
 
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Mean
overall
diameter
Conductor DC
resistance at
20ºC
Approx. Total
Weight
Max. Current Carrying
Capacity at 30ºC
mm2 No. ×mm mm min max Ù/km Kg/km Pip A Air A
0.5 15 × 0.20 0.6 2.1 2.5 39.0 10.0 - -
0.75 22 × 0.20 0.6 2.2 2.7 26.0 12.0 - 16
1 30 × 0.20 0.6 2.4 2.8 19.5 15.0 12 20

 

H07V2-K

450/750V
 

 
Code : H07V2-K
Standard   :     TS 9758, IEC 227, VDE 0281, BS 6004
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
Application :    For protected installation in equipment and lighting fitting.
    Also for in conduit. on and under plaster.
Technical Data   :   Max. operating temperature 90  ºC
    Short circuit temperature 160  ºC


 
Nominal
Cross
Section
Number
and Dia.
Thickness of
insulation
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity
at 30ºC
mm2 No. ×mm mm min max Ù/km Kg/km Pip A Air A
1.5 27 × 0.25 0.7 2.8 3.4 13.3 21.0 15 24
2.5 45 × 0.25 0.8 3.4 4.1 7.98 32.0 20 32
4 50 × 0.30 0.8 3.9 4.8 4.95 48.0 25 42
6 75 × 0.30 0.8 4.4 5.3 3.30 68.0 33 54
10 73 × 0.40 1.0 5.7 6.8 1.91 113 45 73
16 119 × 0.40 1.0 6.7 8.1 1.21 174 61 98
25 182 × 0.40 1.2 8.4 10.2 0.780 282 83 129
35 252 × 0.40 1.2 9.7 11.7 0.554 378 103 158
50 364 × 0.40 1.4 11.5 13.9 0.386 543 132 198

 
 
H05V2V2-F

300/500V




 
Code : H05V2V2-F
Standard  :     TS 9760, IEC 227, VDE 0281, BS 6500
Construction  : 1- Flexible Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application :     In dry. damp and wet locations as flexible connecting cables for light mechanical
    stresses. It is used for hand tools. heat tools and house hold appliances with flat shape.
Technical Data :   Max. operating temperature 90ºC
    Short circuit temperature 160  ºC
 
Num. of Cores and
Nominal Cross
Section
Number
and Dia.
Thickness of
insulation
Thickness
of Sheath
Mean overall
diameter
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying Capacity
at 30ºC
No ×mm2 mm mm   min max Ù/km Kg/km Air A
2 × 0.75 22 × 0.20 0.6 0.8 5.7 7.2 26.0 57.0 8
2 × 1 30 × 0.20 0.6 0.8 5.9 7.5 19.5 64.1 12
2 × 1.5 27 × 0.25 0.7 0.8 6.8 8.6 13.3 91.0 18
2 × 2.5 45 × 0.25 0.8 1.0 8.4 10.6 7.98 135 26
2 × 4 50 × 0.30 0.8 1.1 9.7 12.1 4.95 189 32
2 × 6 75 × 0.30 0.8 1.1 11.8 13.1 3.30 274 42
2 × 10 73 × 0.40 0.9 1.2 14.6 15.8 1.91 422 70
3 × 0.75 22 × 0.20 0.6 0.8 6.0 7.6 26.0 68.1 8
3 × 1 30 × 0.20 0.6 0.8 6.3 8.0 19.5 77.0 12
3 × 1.5 27 × 0.25 0.7 0.9 7.4 9.4 13.3 109 18
3 × 2.5 45 × 0.25 0.8 1.1 9.2 11.4 7.98 169 26
3 × 4 50 × 0.30 0.8 1.2 10.5 13.1 4.95 238 32
3 × 6 75 × 0.30 0.8 1.1 12.5 14.2 3.30 343 42
3 × 10 73 × 0.40 0.9 1.2 15.8 17.2 1.91 538 70
4 × 0.75 22 × 0.20 0.6 0.8 6.6 8.3 26.0 85.0 8
4 × 1 30 × 0.20 0.6 0.8 7.1 9.0 19.5 98.0 12
4 × 1.5 27 × 0.25 0.7 0.8 8.4 10.5 13.3 145 18
4 × 2.5 45 × 0.25 0.8 1.1 11 12.5 7.98 213 26
4 × 4 50 × 0.30 0.8 1.2 11.5 14.3 4.95 306 32
4 × 6 75 × 0.30 0.8 1.3 13.6 15.2 3.30 427 42
4 × 10 73 × 0.40 0.9 1.4 17.2 18.3 1.91 674 70
4 × 16 119 × 0.40 0.9 1.5 19.4 20.8 1.21 972 80
5 × 0.75 22 × 0.20 0.6 0.8 7.4 9.3 26.0 101 8
5 × 1 30 × 0.20 0.6 0.9 7.8 9.8 19.5 125 12
5 × 1.5 27 × 0.25 0.7 1.0 9.3 11.6 13.3 176 18
5 × 2.5 45 × 0.25 0.8 1.1 11.2 13.9 7.98 261 26
5 × 4 50 × 0.30 0.8 1.3 13.0 16.1 4.95 375 32
5 × 6 75 × 0.30 0.8 1.4 15.6 16.8 3.30 524 42
5 × 10 73 × 0.40 0.9 1.5 18.2 20.3 1.91 831 70
 

NVV

300/500V



 
Code : NVV
Standard   :     TS 9759 HD 21,4 S2, VDE 0250-204, BS 6004
Construction  :     1- Solid or Stranded Copper Conductor
    2- PVC insulation              3- PVC Filling                 4- PVC outer sheath
Application :     Fixed wiring in dry and damp premises, in conduits. on or under plaster and on
    insulators over plaster, switching.
Technical Data : Max. operating temperature 70ºC           Short circuit temperature 160ºC

Num. of
Cores and
Nominal
Cross
Section
Number
and Dia.
Thickness
of
insulation
Thickness
of Sheath
Mean overall diameter Conductor
DC
resistance
at 20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No ×mm2 mm mm mm min max Ù/km Kg/km Air A
2 × 1.5 1.35 0.7 1.2 8.4 10.0 12.1 108 22
2 × 2.5 1.73 0.8 1.2 9.6 11.5 7.41 148 30
2 × 4 2.19 0.8 1.2 10.5 12.5 4.61 194 40
2 × 6 2.68 0.8 1.2 11.5 13.5 3.08 250 51
2 × 10 7 × 1.32 1.0 1.4 14.5 16.5 1.83 427 70
2 × 16 7 × 1.66 1.0 1.4 16.5 20.0 1.15 604 94
3 × 1.5 1.35 0.7 1.2 8.8 10.5 12.1 128 22
3 × 2.5 1.73 0.8 1.2 10.0 12.0 7.41 179 30
3 × 4 2.19 0.8 1.2 11.0 13.0 4.61 239 40
3 × 6 2.68 0.8 1.2 12.5 14.5 3.08 319 51
3 × 10 7 × 1.32 1.0 1.4 15.5 17.5 1.83 535 70
3 × 16 7 × 1.66 1.0 1.4 18.0 21.5 1.15 769 94
4 × 1.5 1.35 0.7 1.2 9.6 11.5 12.1 154 18.5
4 × 2.5 1.73 0.8 1.2 11.0 13.0 7.41 219 25
4 × 4 2.19 0.8 1.2 12.0 14.5 4.61 301 34
4 × 6 2.68 0.8 1.2 14.0 16.0 3.08 399 43
4 × 10 7 × 1.32 1.0 1.4 16.5 19.0 1.83 669 60
4 × 16 7 × 1.66 1.0 1.4 20.0 23.5 1.15 970 80
5 × 1.5 1.35 0.7 1.2 10.0 12.0 12.1 181 15.5
5 × 2.5 1.73 0.8 1.2 12.0 14.5 7.41 262 22
5 × 4 2.19 0.8 1.2 13.5 16.0 4.61 364 31
5 × 6 2.68 0.8 1.2 15.0 17.5 3.08 483 40
5 × 10 7 × 1.32 1.0 1.4 18.0 21.0 1.83 828 56.5

 


FLAT CABLES

300/500V



 
Code : Flat Cables
Standard :     TS 9760, IEC 227, VDE 0281, BS 6500
Construction : 1- Solid Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching
       stations, under ground installation, with additional protection where mechanical damage
     is unexpected.
Technical Data :   Max. operating temperature 70ºC
    Short circuit temperature 160ºC



 
Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Thickness of
Sheath
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No. ×mm2 No. ×mm mm mm Ù/km Kg/km Pipe A Air A
2 × 1 1.1 0.6 0.8 18.1 50.0 - 19
2 × 1.5 1.35 0.7 0.8 12.1 66.0 32 20
2 × 2.5 1.73 0.8 1.0 7.41 104 42 20
2 × 4 2.19 0.8 1.1 4.61 143 54 20
3 × 1 1.1 0.6 0.8 18.1 73.0 - 20
3 × 1.5 1.35 0.7 0.9 12.1 101 26 20
3 × 2.5 1.73 0.8 1.1 7.41 158 34 20
3 × 4 2.19 0.8 1.2 4.61 216 44 20

 



FLAT TWIN&THREE CORE

300/500V



 
Code :     FLAT TWIN& THREE CORE CABLES
Standard : BS6004
Construction : 1- Stranded Copper Conductor
    2- PVC insulation
    3- PVC outer sheath
Application :     These Cables are used in dry or damp locations for fixed installation.
    Suitable for installation in walls or embedded in plaster.
Technical Data :   Max. operating temperature 70ºC


 
Num. of Cores
and Nominal
Cross Section
Number
and Dia.
Thickness of
insulation
Thickness of
Sheath
Conductor DC
resistance at
20ºC
Approx.
Total
Weight
Max. Current
Carrying
Capacity at 30ºC
No ×mm2 No. ×mm mm mm Ù/km Kg/km Pipe A Air A
2 × 1.5 7 × 0.51 0.7 0.9 12.1 76..0 32 20
2 × 2.5 7 × 0.66 0.8 1.0 7.41 110 42 27
2 × 4 7 × 0.83 0.8 1.0 4.61 148 54 37
3 × 1.5 7 × 0.51 0.7 0.9 12.1 102 26 18
3 × 2.5 7 × 0.66 0.8 1.0 7.41 152 34 25
3 × 4 7 × 0.83 0.8 1.1 4.61 224 44 34


Packing
Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable

Our workshop
Factory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication CableFactory Wholesale Rvv 6core Cables 0.3 0.5 0.75 1.0 1.5 2.5sq mm Flexible Computer Communication Cable
Range of Business: 

Cables
Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires

Cable Accessories
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f.   Branch Joint
g. Dry and Y shape Branch Joint


Why choose us? 
1. Export to many countries including Iraq, Tanzania and Australia and USA.
2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices. 
3. Professional overseas team guarantees you best pre-and-after sale services.
4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
5. 5S Management to enhance the qualifications of staff and make better service for customers. 
6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.  

Send your message to this supplier

*From:
*To:
avatar Ms. Cecilia Zhang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Ms. Cecilia Zhang
Sales Director
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
308000000 RMB
Plant Area
>2000 square meters