• ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
  • ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
  • ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
  • ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
  • ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
  • ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor

ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor

Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: Bare
Sheath Material: PVC
Material Shape: Round Wire
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ABC
Wire Core Material
Aluminum
Certification
ISO, CCC
Model
ABC
Brand
Yunfeng
Transport Package
Drum
Specification
3x95+1x50
Trademark
YUNFENG
Origin
China
HS Code
7614900000
Production Capacity
500000m/Week

Product Description

 


Self-supporting LV-ABC Lines
Code: ABC 0.6/1kV, NFA2X, AsXS (n), 1-AES
Standards: HD 626 S1: 1996 Part 4-Section F,
PL WT92/K396, CSN 34761-4F
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors with XLPE insulation.
Application: Aerial Bundled Conductors are used
for tributary networks of power buildings
and their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors

Cross section Conductor diameter Thickness of insulation Core diameter Current carrying capacity Breaking load
(mm²) min. max. nom. min. min. (A*) (kN)
(mm) (mm) (mm) (mm) (mm)
16 4,6 5,1 1,2 1,00 7,8 - 2,60
25 5,6 6,5 1,3 1,07 10,1 107 4,17
35 6,6 7,5 1,3 1,07 11,0 132 5,78
50 7,7 8,6 1,5 1,25 12,5 165 8,45
70 9,3 10,2 1,5 1,25 14,0 205 11,32
95 11,0 12,0 1,7 1,50 16,1 - 15,30
120 12,5 13,5 1,8 1,60 17,6 - 20,00
150 13,9 15,0 1,8 1,60 18,8 - 25,00
* defined for ambient temperature of 35°C and max. conductor temperature of 80°C

Dimensions of neutral messenger conductors
Number of phase cores x cross section Bundle diameter
+ public lighting conductors approx.
+ neutral cross section  
(mm²) (mm)
2 x 16 15
2 x 25 18
2 x 35 20
4 x 16 18
4 x 25 22
4 x 35 25
4 x 50 28
4 x 70 32
4 x 70 + 1 x 35 36
4 x 70 + 2 x 35 40
4 x 95 37
4 x 120 40
4 x 120 + 2 x 35 43
4 x 150 44

ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor
LV-ABC Lines with Bare Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 5-Section D,
 AMKA (SFS 2200)
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors 
Application: Aerial Bundled Conductors are used for
          tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors
Cross section Conductor diameter Thickness of insulation Core diameter Current carrying capacity Breaking load
(mm²) min. tolerance nom. min. min. max. (A*) (kN)
(mm) (mm) (mm) (mm) (mm)  
16 4,4 ±0,05 1,4 - 7,1 7,3 70 -
25 5,9 ±0,02 1,4 - 8,3 9,1 95 -
35 6,9 ±0,02 1,6 - 9,7 10,5 115 -
50 8,1 ±0,25 1,6 - 10,8 11,8 140 -
70 9,7 ±0,25 1,8 - 12,8 13,8 180 -
120 12,8 ±0,30 2,0 - 16,2 17,4 250 -
* defined for ambient temperature of 25°C and max. conductor temperature of 70°C

Dimensions of neutral messenger conductors
Cross section Conductor diameter Thickness of insulation Core diameter Current carrying capacity Breaking load
(mm²) min. max. nom. min. min. max. (A*) (kN)
(mm) (mm) (mm) (mm) (mm) (mm)
25 5,9 ±0,02 - - 5,5 6,3 - 7,4
35 6,9 ±0,02 - - 6,5 7,3 - 10,3
50 8,1 ±0,25 - - 7,6 8,6 - 14,2
70 9,7 ±0,25 - - 9,2 10,2 - 20,6
95 11,4 ±0,30 - - 10,8 12,0 - 27,9

Dimensions of Cable Bundle
Number of phase cores x cross section Bundle diameter
+ neutral cross section approx.
(mm²) (mm)
1 x 16 + 25 15
3 x 16 + 25 22
4 x 16 + 25 22
3 x 25 + 35 26
4 x 25 + 35 26
3 x 35 + 50 30
3 x 50 + 70 35
3 x 70 + 95 41
3 x 120 + 95 47

ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor

LV-ABC Lines with Insulated Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 6-Section E,
 AMKA (SFS 2200)
Construction: Aluminum conductors with XLPE insulation. 
Application: Aerial Bundled Conductors are used for
          tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross section Conductor diameter Thickness of insulation Core diameter Current carrying capacity Breaking load
(mm²) min. max. nom. min. min. max (A*) (kN)
(mm) (mm) (mm) (mm) (mm)  
16 4,6 5,1 1,2 - 7,0 7,8 - -
25 5,8 6,3 1,4 - 8,6 9,4 112 -
35 6,8 7,3 1,6 - 10,0 10,9 138 -
50 7,9 8,4 1,6 - 11,1 12,0 168 -
70 9,7 10,2 1,8 - 13,3 14,2 213 -
95 11,0 12,0 1,8 - 14,6 15,7 258 -
120 12,0 13,1 1,8 - 15,6 16,7 306 -
150 13,9 15,0 1,7 - 17,3 18,6 344 -
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of neutral messenger conductors
Cross section Conductor diameter Thickness of insulation Core diameter Current carrying capacity Breaking load
(mm²) min. max. nom. min. min. max (A*) (kN)
(mm) (mm) (mm) (mm) (mm)  
54,6 9,2 9,6 1,6 - 12,3 13,0 - 16,6
70 10,0 10,2 1,5 - 12,9 13,6 - 20,5
95 12,2 12,9 1,6 - 15,3 16,3 - 27,5
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of Cable Bundle
Number of phase cores x cross section Bundle diameter
+ public lighting conductors approx.
+ neutral cross section  
(mm²) (mm)
3 x 25 + 54,6 30,0
3 x 35 + K x 16 + 54,6 33,0
3 x 50 + K x 16 + 54,6 36,0
3 x 70 + K x 16 + 54,6 37,5
3 x 70 + K x 25 + 54,6 40,0
3 x 70 + K x 16 + 70 41,0
3 x 95 + K x 16 + 70 44,0
3 x 120 + K x 16 + 70 46,0
3 x 120 + K x 16 + 95 47,0
3 x 150 + K x 16 + 70 48,0
3 x 150 + K x 16 + 95 49,0

Note: K number of public lighting conductors (K can be equal to 0, 1, 2, or 3)

ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor

Packing
ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorOur wokshop
ABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC ConductorABC-0.6/1kv 3X95+1X50 Aerial Bundle Cable Low Volatge Overhead Conductors PVC Conductor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now